Productomschrijving
The ACV ratio reducing valve maintains a fixed ratio between upstream and downstream pressure: as inlet pressure varies, the outlet pressure varies proportionally. This is particularly useful on systems where demand patterns cause large upstream pressure fluctuations, as it avoids the very low outlet pressures that a fixed-set-point PRV would deliver at low inlet pressures. Fully hydraulic, no external power required.
Technische specificaties
DiameterreeksDN50–DN400
DrukPN16
MateriaalDuctile iron body, rubber-lined diaphragm, stainless pilot
AansluitingFlanged to EN 1092-2 PN16
Goedkeuringen en certificeringen
WRASWater Regulations Advisory Scheme: UK approval for use in drinking water systemsISO 9001International quality management system certification
Normen
EN 1074-5
Typische toepassingen
- Trunk main pressure management
- Variable inlet pressure systems
- District metered areas
- Pressure zone management

Offerte aanvragen
Stuur ons uw nominale diameter, druk en hoeveelheid en wij reageren met prijzen en volledige technische documentatie, doorgaans binnen één werkdag.
Offerte aanvragen of e-mail naar info@afcvalves.euIn één oogopslag
- Diameters
- DN50–DN400
- Druk
- PN16
- Aansluiting
- Flanged to EN 1092-2 PN16
Categorie

Drukreduceerventielen
1 product